specifications
The thermocouple protection tube adopts a special structure, so that it is closely attached to the inside of the cracking furnace tube without affecting the material flow. It is suitable for temperature measurement and control of cracking furnace in the production process of ethylene.
Electrical outlet: M20X1.5, NPT1/2
Connection size: M27X2, NPT3/4
Protection level: IP65
Flameproof level: D‖CT6
Accuracy class: Class I
Generally, it refers to the static external pressure that the protection tube can withstand without breaking at normal temperature. The test pressure is generally 1.5 times the nominal pressure. In fact, the allowable nominal pressure is not only related to the material, diameter and wall thickness of the protection tube, but also It is related to its structural form, installation method, insertion depth, and flow velocity and type of measured medium.
The thermal resistance is 15-35°C, the relative humidity is not more than 80%, and the test voltage is 10-100V (DC). The insulation resistance between the electrode and the outer sleeve is ≥100MΩ.
The temperature of the thermocouple is 20±15°C, the relative humidity is not more than 80%, and the test voltage is 500±50V (DC). The insulation resistance between the electrode and the outer sleeve is ≥1000Ω.M